제품 상세 설명 - SL

제품명: SL Series 10W-1.2kW Rack Mount Power Supply
기계적 구성: Rack
파워: 10W, 30W, 60W, 150W, 300W, 600W, 1.2kW
출력 전압: 17 different maximum voltage ratings from 1 to 130kV
PDF: 제품 설명 PDF 자료를 다운로드하십시오
Manual: Download Manual
견적서 받기

Spellman’s SL Series of high voltage power supplies are designed to meet uncompromising performance stan­dards in a minimum of space. Their circuitry includes a resonant high frequency inverter with proprietary control which provides fault-free operation in extreme transient and arcing environments with greater than 85% efficiency. These full featured supplies are available in a wide range of outputs with many options.SL High Voltage Power Supply


  • Very Compact and Lightweight
  • Low EMI and RFI
  • Voltage Range from 1kV to 130kV
  • Reversible Polarity Standard up to 6kV
  • System Status Indicators
  • Extensive Analog and Digital Interface
  • Arc Quench/Arc Count/Arc Trip
  • OEM Customization Available

 

TYPICAL APPLICATIONS

Analytical X-ray  Capacitor Charging 
CPT/CRT Testing Hipot Testing
Electrostatics General Laboratory
E-Beam Systems CW Lasers

OPTIONS

See SL options and descriptions below.

SPECIFICATIONS 

Status Indicators:

Voltage and Current Control Mode, Interlock Open and Closed, High Voltage Inhibit, Overcurrent and Overvoltage,Arc, Regulation Error, Overtemperature, Over Power (Optional).

Input:

115Vac or 220Vac±10%, 50/60Hz. Specify with order. 1200W model available in 200/220Vac only. 

Output:

Models available from 1kV to 130kV. Each model is available in positive, negative or reversible polarity output. 

Front Panel Controls:

Voltage and current are continuously adjustable by ten-turn potentiometers with lockable counting dials, ON/OFF circuit breaker/lamp, high voltage ON switch/indicator and high voltage OFF switch/indicator.

Voltage Regulation:

Load: 0.005% of maximum voltage +500mV for full load change.

Line: ±0.005% of full voltage +500mV over specified input range 

Current Regulation:

Load: 0.01% of maximum current ±100µA for full voltage change.

Line: ±0.005% of maximum current for a ±10% input line change.

Ripple:

0.1% p-p +1Vrms.

Temperature Coefficient:

100ppm/°C voltage or current regulated. Higher stability is available on special order.

Environmental:

Temperature Range:

Operating: 0°C to 50°C.

Storage: -40°C to 85°C.

Humidity: 10 to 90% relative humidity, non-condensing

Stability:

100ppm/hour after 1/2 hour warm-up for both voltage and current regulation.

Metering:
Digital voltage and current meters, 31/2
digit ±1 least significant digit.

Output Cable:
10’ (3.05m) of shielded high voltage
cable removable at the rear panel.

AC Line Input Cable:

10 to 300W: IEC320 Cord Set, 6’ (1.83m) 600 to 1200W: 3-conductor, 12AWG, 6’ (1.83m) cable permanently attached to unit.

Dimensions:

10W – 300W: 13/4”H(1U) x 19”W x 19”D**
(4.45cm x 48.3cm x 48.3cm).
600W – 1200W: 31/2”H(2U) x 19”W x 19”D**
(8.9cm x 48.3cm x 48.3cm).
**Depth becomes 24” (60.7cm) for 80 to 130kV ranges.

Weight:

17 to 30lbs (7.7 to 14kg) depending on model.

Regulatory Approvals:

Compliant to 2004/108/EC, the EMC Directive and 2006/95/EC, the Low Voltage Directive. Compliant to 2002/95/EC, RoHS

SL SELECTION TABLE- 10W, 30W, 60W 1.75" (1U)

  10 Watt 30 Watt 60 Watt
kV mA Model mA Model mA Model
1 10 SL1PN10 30 SL1PN30 60 SL1PN60
2 5 SL2PN10 15 SL2PN30 30 SL2PN60
3 3.3 SL3PN10 10 SL3PN30 20 SL3PN60
6 1.7 SL6PN10 5 SL6PN30 10 SL6PN60
8 1.25 SL8PN10 3.75 SL8PN30 7.5 SL8PN60
10 1.0 SL10*10 3 SL10*30 6 SL10*60
15 0.67 SL15*10 2 SL15*30 4 SL15*60
20 0.50 SL20*10 1.5 SL20*30 3 SL20*60
30 0.33 SL30*10 1.0 SL30*30 2 SL30*60
40 0.25 SL40*10 0.75 SL40*30 1.5 SL40*60
50 0.20 SL50*10 0.60 SL50*30 1.2 SL50*60
60 0.17 SL60*10 0.50 SL60*30 1.0 SL60*60
70 0.14 SL70*10 0.43 SL70*30 0.85 SL70*60
80 0.13 SL80*10 0.38 SL80*30 0.75 SL80*60
100 0.10 SL100*10 0.30 SL100*30 0.60 SL100*60
120 0.10 SL120*10 0.25 SL120*30 0.50 SL120*60
130 0.10 SL130*10 0.25 SL130*30 0.46

SL130*60

*Specify “P” for positive, “N” for negative, or “PN” for reversible polarity. Higher voltage models available on special order.

SL SELECTION TABLE- 150W, 300W 1.75" (1U)

  150 Watt 300 Watt
kV mA Model mA Model
1 150 SL1PN150 300 SL1PN300
2 75 SL2PN150 150 SL2PN300
3 50 SL3PN150 100 SL3PN300
6 25 SL6PN150 50 SL6PN300
8 18.75 SL8PN150 37.5 SL8PN300
10 15 SL10*150 30 SL10*300
15 10 SL15*150 20 SL15*300
20 7.5 SL20*150 15 SL20*300
30 5.0 SL30*150 10 SL30*300
40 3.75 SL40*150 7.5 SL40*300
50 3.00 SL50*150 6.0 SL50*300
60 2.50 SL60*150 5.0 SL60*300
70 2.1 SL70*150 4.28 SL70*300
80 1.90 SL80*150 3.75 SL80*300
100 1.50 SL100*150 3.00 SL100*300
120 1.25 SL120*150 2.50 SL120*300
130 1.15 SL130*150 2.30 SL130*300

 *Specify "P" for positive, "N" for negative, or "PN" for reversible polarity. Higher voltage models available on special order.

SL SELECTION TABLE- 600W, 1200W

  600 Watt 1200 Watt
kV mA Model mA Model
1 600 SL1PN600 1200 SL1PN1200
2 300 SL2PN600 600 SL2PN1200
3 200 SL3PN600 400 SL3PN1200
6 100 SL6PN600 200 SL6PN1200
8 75 SL8PN600 150 SL8PN1200
10 60 SL10*600 120 SL10*1200
15 40 SL15*600 80 SL15*1200
20 30 SL20*600 60 SL20*1200
30 20 SL30*600 40 SL30*1200
40 15 SL40*600 30 SL40*1200
50 12 SL50*600 24 SL50*1200
60 10 SL60*600 20 SL60*1200
70 8.6 SL70*600 17 SL70*1200
80 7.5 SL80*600 15 SL80*1200
100 6.0 SL100*600 12 SL100*1200
120 5.0 SL120*600 10 SL120*1200
130 4.6 SL130*600 9.2 SL130*1200

*Specify "P" for positive, "N" for negative, or "PN" for reversible polarity. Higher voltage models available on special order.

SL TERMINAL BLOCK 26 PIN

Pin Signal Signal Parameters
1 Power Supply Common Signal Ground
2 External Inhibit Ground=Inhibit, Open=HV On
3 External Interlock +15V at Open, <15mA at Closed
4 External Interlock Return Return for Interlock
5 Current Monitor 0 to 10V=0 to 100% Rated Output
6 kV Test Point 0 to 10V=0 to 100% Rated Output
7 +10Vdc Reference +10Vdc, 1mA Max
8 Remote Current Program In 0 to 10V=0 to 100% Rated Output
9 Local Current Program Out Front Panel Program Voltage
10 Remote Voltage Program In 0 to 10V=0 to 100% Rated Output
11 Local Voltage Program Out Front Panel Program Voltage
12 Power Monitor 0 to 10V=0 to 100% Rated Output (Optional)
13 Remote Power Program In
14 Local HV Off Out +15V at Open, <25mA at Closed Connect to HV OFF for FP Operation
15 HV Off
16 Remote HV On +15V, 10mA Max=HV Off
17 Remote HV Off Indicator 0=HV On, +15V, 10mA Max=HV Off
18 Remote HV On Indicator 0=HV Off, +15V, 10mA Max=HV On
19 Remote Voltage Mode Open Collector 35V Max, 10mA Max On=Active
20 Remote Current Mode
21 Remote Power Mode
22 Remote PS Fault 0=Fault, +15V, 0.1mA Max=No Fault
23 +15V Output +15V, 100mA Max
24 Power Supply Common Signal Ground
25 Spare Spare
26 Shield Return Chassis Ground



How To Order:
Sample model number: SL80PN1200/NSS/DPM4

There may be some restrictions on multiple option combinations. Please contact our Sales department for more details.



DIMENSIONS: in.[mm]
 
10W-300W

FRONT VIEW
 
SL High Voltage Power Supply
 TOP VIEW
 
SL High Voltage Power Supply
 BACK VIEW
 Spellman SL High Voltage Power Supply
 
  600W-1200W
 
 FRONT VIEW
 SL High Voltage Power Supply
 TOP VIEW
 SL High Voltage Power Supply
 
 BACK VIEW
 Spellman SL High Voltage Power Supply

SL Series Options

AOL Adjustable Overload Trip: A control board jumper is moved to make the power supply shut down if it ever operates in current mode. This allows the user to set the cur­rent programming level as a trip point that will turn the power supply off with an Over Current fault if it ever tries to operate in Current Mode.

APT Adjustable Power Trip: A third control loop is installed in the power supply, a power loop. This power loop uses an analog multiplier chip to multiply the voltage and current feedback signals to create a power feedback signal. Programming and feedback scaling is 0­10Vdc = 0-100% of rated power. The circuit is configured to trip the power supply off with an Over Power fault if the power loop ever tries to regulate.

AT Arc Trip: A control board jumper is moved such that the first arc sensed will shut the power supply off with an ARC fault.

BPM Bipolar Master

BPS Bipolar Slave - This option configures two identical but opposite polarity units to function as a single tracking bipolar supply. The voltage feedback of the master (positive unit) is provided to the voltage programming input of the slave (negative unit).

CMS Current Mode Select - A front panel switch is provided to allow the power supply to either regulate in current mode or create an over current fault when operated in current mode, which will shut down the supply. This is basically a switch selectable AOL option.

CPC Constant Power Control - Identical to the APT Option with the exception the power supply will run and regulate when the power loop becomes active.

DPM4  Digital Panel Meter, 4.5 digits  - The standard 3.5 digit front panel meters are replaced with 4.5 digit panel meters.

EFR  External Fault Relay - A set of relay contacts are provided via the rear panel interface that will change state if the power supply shuts down due to a fault condition.

FCV  Fine Control Voltage - This option adds a second potentiometer to the front panel of the unit. This allows for a finer local adjustment of the output voltage setting.

FG  Floating Ground - All the analog returns inside the power supply are isolated from chassis and brought to one point on the rear panel. Any current that flows out of the power supply via the HV cable/connecter on the high side must return back to the multiplier via the load return on the low side. With only one path to flow through on the low side, a current meter can be inserted in series and a safe ground referenced measurement can be made of the actual high voltage output current.

FGLL  Floating Ground Low Leakage - Identical functionality as the FG Option but a shield is placed around the high voltage multiplier to capture any leakage current inside the power supply and return it to the top of the current sense resistor. This negates any internal leakage currents from effecting measurements being made.

IO  Instant On - A jumper is placed between TB1-15 and TB1-16 on the rear panel, causing the power supply to automatically toggle into HV ON when ever the line voltage is applied.

LL(X)  Lead Length - Extra long high voltage output cable. 20, 40, 60
and 100 feet are standard lengths.

LR  Low Ripple - Done on a case by case basis, the standard unit is evaluated and modifications are done to improve the output ripple to 0.05% peak to peak. The operating frequency might be increased, or additional filtering may be added to the HV multiplier.

NAD  No Arc Detect - This option removes the arc intervention circuitry from the power supply. Care must be exercised when using this option as damage to the HV multiplier could occur.

NSS  No Slow Start - The standard 6 second long linear ramp of output voltage is removed allowing the high voltage to “step” to its set point when enabled.

PN Positive/Negative - Reversible polarity option. Units that are not inherently reversible by design (10kV to 130kV) can have their output polarity reversed by the process of exchanging the high voltage multiplier section.

RFR  Remote Fault Reset - This option provides the ability to reset any power supply faults that might occur via toggling a signal on the rear panel interface.

ROV  Remote Over Voltage - The programming signal for the over voltage comparator circuit is made available to the customer remotely, allowing the power supply to be set to trip the OVP circuit anywhere from 0-110% of rated output voltage.

SL Slides - Industry standard rack mounted slides are installed on the power supply.

SS(X) Slow Start(X) - The standard slow start is modified to provide a time of (X) seconds. Time frames of 0.1 seconds to 120 seconds can be accommodated.

There may be some restrictions on multiple option combinations.
Please contact our Sales department for more details.